Bosch EA500B Security Escort Transponder w/o encl. 4.998.800.319
Sends alarm and test signals from the receiver to the central console Supports a combined total of 64 receivers and alert units Uses AC power with battery backup for all receivers Provides power to SE485 interface and spread spectrum radio Monitors receivers and alert units ten times per second for alarms, tests, tamper notification, and power loss Reports alarms, tests, tamper notification, AC power loss, and backup battery status Alarm Output 2 (1 for the strobe and 1 for the siren) Keyswitch Input Requires optional, supervised loop, 47 kΩ EOL resistor Mounting Indoor only Tamper Output NC; optional (CTS1-70) Trouble Output Through central console Battery Backup: 12 VDC 7 Ah lead acid Power Output: 9 VDC output for SE485 or for ProxLink Radio Module power Primary Power Requirement: 18